Choose Your Solar Bi-Fan Retrofit Model
|
ABF-12-RF Aura Solar Fan Retrofit Specs
|
----------- D I M E N S I O N S -----------
ABF-12-RF Aura Solar Bi-Fan
12" Diameter Retrofit
|
|
Inside Dia. (A)
|
Outside Dia. (B)
|
Height of Head (C)
|
Max. Pitch Capacity
|
Net Free Vent Area (in.)
|
Net Free Vent Area (feet)
|
Application
per sq. ft.
|
|
12
|
16
|
8
|
7/12
|
113
|
.78
|
450
|
|
Fan Rating with Solar Power On
|
A/C Fan
|
|
Solar
Module
|
Voltage
|
Motor Wattage
|
# of Fans
|
Total Fan Watts
|
Total Solar Power CFM
|
Total A/C Power CFM
|
|
10 W
|
12 V
|
1.8
|
4
|
7.2
|
174
|
261
|
|
CFM Performance Testing using wind only
|
|
4 mph
|
5.2 mph
|
7.4 mph
|
9.8 mph
|
11 mph
|
|
120 cfm
|
135 cfm
|
227 cfm
|
270 cfm
|
310 cfm
|
|
|