Aura Gravity Ventilator | 48″ Diameter 6″ Tall Collar | 1808 Sq. In. NFA | Model AV-48-C6

$1,138.00

Plus Shipping
 and Options
Specifications
Image Gallery
Description
Colors
Drawings
Installation
Vent Calculator
Add To Cart

48 inch Roof Vent | Aura Gravity Ventilator | Model AV-48-C6

The 48 inch Aura Gravity Vent is 48 inches in diameter and has a 6 inch tall collar. The model AV-48-C6 has 1,808 inches of Net Free Area (NFA). All 48 inch gravity vents come with a standard 54″ x 54″ square flange.

Benefits:

  • Energy efficient
  • Inner louvers prevent insects and animals from entering the vent
  • Round aerodynamic design can withstand harsh weather and wind forces beyond 200 mph
  • Vent head is removable for easy installation
  • Noiseless – does not require electricity to exhaust air

Where to Install:

Exhaust vents with a collar height of 6 inches or greater are typically for low slope or flat roof ventilation. However, if installed less than 4 feet from the peak, this roof vent can go on a 0/12 to 3/12 pitch roof in climate zones 1-6. See the installation guides for help installing.

48 inch diameter roof vents are industrial size, therefore, should be in industrial settings. For those looking to ventilate their homes, please view roof vents with a smaller diameter.

How it Operates:

The Aura Gravity Ventilator works like a roof turbine but with no moving parts.

Aura Gravity Ventilators rely on the Venturi Effect which occurs when the wind blows against the outer louvers. It creates a spinning upward draft through the vent allowing air to dynamically flow out of the vent. Even the smallest breeze can create exhaust ventilation to draw out air from the vent.

The Aura Gravity Roof Vents are made of durable rust-free aluminum. The vent head has a flat one-piece spun lid that prevents rain and snow from entering the vent. The round aerodynamic design can withstand harsh weather and wind forces beyond 200 mph. Therefore, wind speeds of 11 mph for a 48 inch Gravity Ventilator produces 5,711 CFM of air exhaust for attic ventilation.

The inner louvers of the roof vent prevent insects and animals from entering the attic. The louvers also allow the air to flow freely to the outside.

AVP’s Aura Gravity Vents are UL Listed and rated up to 50+ PSF or wind pressure above 200 MPH.  Certified by Texas Department of InsuranceFlorida State Approved & Conforms to the Standards of CALFIRE.

For any questions please see the frequently asked questions page. If you still have questions, email the sales team at [email protected] or call 845-565-7770.

Colors
RAL Color Chart

Click below to see or download full technical drawing for this product

dwg file icon - click to download CAD (dwg) fileunmarked drawingpdf file icon - click to download pdf filedwg file icon - click to download CAD (dwg) fileannotated drawingpdf file icon - click to download pdf filedwg file icon - click to download CAD (dwg) filecut away drawingpdf file icon - click to download pdf fileRevit File drawingrfa file icon - click to download CAD (rfa) file

Click below to see or download full Installation Instructions for this product

Shingled Roof - pdfFlat Roof - pdf
N/AInstallation Instructionpdf file icon - click to download pdf file

Calculate number of Model AV-48-C6 Vents Needed for a Given Area

Enter the Width and Length of the attic space you need to ventilate to calculate the area. You may also enter the area directly in the "Area" field. It is not necessary to hit the Return or Enter key (which will refresh this page), just enter numbers in the fields.


Enter width of space to calculate area (or enter Area below)


Enter width of space to calculate area (or enter Area below)


If you know it, you may enter the area directly here

The diameter size of all roof vents determines the Net Free Area, also known as the "NFA". NFA is the measured amount of opening each vent offers at each specific size. to be available for venting air through a specific vent size. The calculator below will find the overall number of vents needed to effectively ventilate the targeted attic space.

Once you have the area, the numbers shown below are the number of vents of that size which would ventilate the specified area with both 1/300 and 1/150 rule.

Results Appear Here





*Please note
The roof vent calculation values shown above are for the exhaust portion of the roof. The same amount of net free air inches is needed for air intake as well. Proper roof ventilation consists of 50% air exhaust and 50% air intake.


Select Options and Click "Add To Cart" button below

Base Price (Not Including Shipping and Options):

$1,138.00

Our products can be painted with a durable baked-on powder coating surface finish.
Click in a color square to choose a paint color.
Click "Premium Colors" to see the full set of color options.












Brand: Active VentilationUPC(GTIN): 843951000848 SKU: AV-48-C6 Category:
linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram