Air Exhaust Roof Louver | 14″ Diameter 1″ Tall Collar PV-14-C1
Base Price Each:
$50.00
- Specifications
- Image Gallery
- Drawings
- Installation Guides
- Placement Instructions
- Florida Approval
- Texas Approval
- UL Certificate
- Add to Cart
- Description
- Shipping Dimensions
Pop Roof Vent - Installation Instructions
Product Link | Installation Instructions (Shingled Roof) - pdf | Installation Instructions(Flat Roof) - pdf |
---|---|---|
PV-14-C01 | ![]() | N/A |
Click the Logo to see the full documentation of Active Ventilation Products approvals on the Florida DBPR web site.
Active Ventilation Products Pop Vent series has been tested and approved by the State of Florida

Our Pop Vents have UL Certification. Check out other details and specifics on
The Pop Vent “Roof Louver” is used for ventilating steep slope roofs. PV-14-C01 is a 14 inch in diameter roof vent that has a 1 inch tall collar. This means that the vent has a 1 inch clearance between the base and the inner louvers. The PV-14-C01 has 144 inches of net free area (NFA) and comes with a 19 X 19 square base or flange. When used for roof exhaust the PV-14-C01 can be used in climate zones 1 through 8 if the roof pitch is 4/12 or greater and the vent is no more than 12 inches down from the peak of the roof.
Model PV-14-C01 will alleviate moisture in the winter and heat in the summer and extend the life of the roof. The Pop Vent’s top (lid) is manufactured and spun out of one solid piece of aluminum making it corrosion resistant.
The Pop Vents louvers allow hot air to escape freely and efficiently while keeping out birds, insects and animals out of the attic. The round aerodynamic design can with stand harsh weather and wind pressure exceeding 200 mph.
The 14 inch Pop Vent is great for residential roof applications because it is low profile and that it can be painted to match the color of the asphalt shingles.
- Excellent choice to removing radiant heat from attic spaces in the summer
- Helps to keep insulation dry in the winter
- Pitch capacity range: 3/12 to 12/12
- Inner cylinder louver design does not allow accumulation of particle build up as found in use of insect screen
- Built-in inner vertical louver cylinder has a 1/8th in. opening between the louver blades meets the requirements of California building code 706A.2 vents to resist the intrusion of burning embers and flame through ventilation openings confirmed by Underwriters Laboratories
- Helps to reduce energy costs
Pop Vents are UL Listed and rated up to 50+ PSF or wind pressure above 200 MPH. Certified by Texas Department of Insurance, Florida State Approved & Conforms to the Standards of CALFIRE.
Actual Package Weight | 10 lbs |
---|---|
Dimensions | 20 × 20 × 10 in |
UPS Dimensional (Billable) Weight | 29 lbs |
Manufacturer | Active Ventilation Products |