Air Exhaust Roof Louver | 12″ Diameter 1″ Tall Collar | 113 Sq. In. NFA | Model PV-12-C1

$46.00

Plus Shipping
 and Options
Specifications
Image Gallery
Florida Approval
Texas Approval
UL Certification
Description
Colors
Drawings
Installation
Vent Calculator
Add To Cart
CERTIFIED-UL Logo

This product has UL Certification. Check out other details and specifics on UL Product IQ™ (Note: UL now requires you to have a free account to access this page) UL’s Online Certifications Directory.

certificate-of-compliance-pop-vent

Air Exhaust Roof Louver | Pop Vent | PV-12-C1

The 12 inch Pop Vent Roof Louver is for ventilating steep slope roofs. The PV-12-C1 is a 12 inch diameter roof vent with a 1 inch tall collar. In other words, this vent has 1 inch of clearance between the base and the inner louvers. The vent has 113 inches of net free area (NFA) and comes with an 18” x 18” square flange.

Where to Install:

If installed on the upper portion of the roof, no more than 1 foot down from the peak, this attic vent can go on a roof with a pitch of 3/12 or greater in all climate zones.

The 12 inch Pop Vent roof louver is ideal for residential roof applications because of its low profile. It can also be painted to match the color of the asphalt shingles.

To determine the number of vents you may need, see our Vent Calculator.

How it works:

The Air Exhaust Roof Louver removes moisture in the winter and heat in the summer to extend the life of the building structure. It helps keep insulation dry in the winter to prevent mold. In addition, the round design is aerodynamic to withstand wind speeds in excess of 200 mph.

This roof vent's lid is one solid piece of aluminum. Thus making this roof vent both durable and corrosion resistant.

The inner louvers are 1/8 inch wide allowing air to flow freely through the vent while preventing insects from entering. The inner louvers meet the requirements of California building code and work better than insect screens.

For any questions please see the frequently asked questions page. If you still have questions, email the sales team at [email protected] or call 845-565-7770. If you are looking to determine the pitch of your roof, see the Roof Pitch Diagram.

Pop Vents are UL Listed and rated up to 50+ PSF or wind pressure above 200 MPH.  Certified by Texas Department of Insurance, Florida State Approved & Conforms to the Standards of CALFIRE.

Colors
RAL Color Chart

Click below to see or download full technical drawing for this product

Pop Vent

Product LinkDrawing- UnmarkedDrawing- AnnotatedDrawing- Cut Away Revit
PV-12-C1dwg file icon - click to download CAD (dwg) fileunmarked drawingpdf file icon - click to download pdf file
dwg file icon - click to download CAD (dwg) fileannotated drawingpdf file icon - click to download pdf file
dwg file icon - click to download CAD (dwg) filecut away drawingpdf file icon - click to download pdf file
Revit File drawingrfa file icon - click to download CAD (rfa) file

Click below to see or download full Installation Instructions for this product

Shingled Roof - pdfFlat Roof - pdf
Installation Instructionpdf file icon - click to download pdf fileN/A

Calculate number of Model PV-12-C1 Vents Needed for a Given Area

Enter the Width and Length of the attic space you need to ventilate to calculate the area. You may also enter the area directly in the "Area" field. It is not necessary to hit the Return or Enter key (which will refresh this page), just enter numbers in the fields.


Enter width of space to calculate area (or enter Area below)


Enter width of space to calculate area (or enter Area below)


If you know it, you may enter the area directly here

The diameter size of all roof vents determines the Net Free Area, also known as the "NFA". NFA is the measured amount of opening each vent offers at each specific size. to be available for venting air through a specific vent size. The calculator below will find the overall number of vents needed to effectively ventilate the targeted attic space.

Once you have the area, the numbers shown below are the number of vents of that size which would ventilate the specified area with both 1/300 and 1/150 rule.

Results Appear Here





*Please note
The roof vent calculation values shown above are for the exhaust portion of the roof. The same amount of net free air inches is needed for air intake as well. Proper roof ventilation consists of 50% air exhaust and 50% air intake.


Select Options and Click "Add To Cart" button below

Base Price (Not Including Shipping and Options):

$46.00

Our products can be painted with a durable baked-on powder coating surface finish.
Click in a color square to choose a paint color.
Click "Premium Colors" to see the full set of color options.












Brand: Active VentilationUPC(GTIN): 843951002170 SKU: PV-12-C1 Category:
linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram