Model PV-16-C8 | Pop Vent | 16" Diameter | 8" Tall Collar | Flat Falng | 200 Sq. In. NFA

Model PV-16-C8 | Pop Vent | 16" Diameter | 8" Tall Collar | Flat Falng | 200 Sq. In. NFA

SKU:PV-16-C8

843951007496

Price:Regular price $134.00 USD

Regular price Sale price $134.00 USD
Sale Sold out
  • Aluminum Unpainted

    Aluminum Unpainted
  • Plain White STANDARD+$30

  • Plain Black STANDARD+$30

  • Pine Green STANDARD RAL 6028+$30

  • Quartz Grey [Weatherwood] STANDARD RAL 7039+$30

  • Terra Brown STANDARD RAL 8028+$30

Color

View full details
Roof Louver for Air Intake - Pop Vent PV-16-C8
Model PV-16-C8  | Pop Vent |  16" Diameter |  8" Tall Collar | Flat Falng | 200 Sq. In. NFA
Drawings
Model PV-16-C8  | Pop Vent |  16" Diameter |  8" Tall Collar | Flat Falng | 200 Sq. In. NFA
Drawings
Model PV-16-C8  | Pop Vent |  16" Diameter |  8" Tall Collar | Flat Falng | 200 Sq. In. NFA
Drawings

16-inch Intake Roof Vent | Pop Vent Model PV-16-C8

The 16-inch Pop Vent Air Intake Vent is ideal for proper attic ventilation. The PV-16-C8 is 16 inches in diameter with an 8-inch tall collar. In other words, this vent has 8 inches of clearance between the base and the inner louvers. In addition, the 16-inch Pop Vent has 200 inches of Net Free Area (NFA) and a standard 24” x 24” flat flange.

Air intake vents allow outside air to enter into attics and ventilation spaces.

Installation: Ideal for low slope or flat roofs

16-inch diameter roof vents are commercial in size and, therefore, ideal for commercial settings. For those looking to ventilate their homes, please view roof vents with a smaller diameter.

This 16-inch attic vent is suitable for climate zones 1-6. This intake roof vent should be near the lower end of the roof.

To determine the number of vents you may need for proper attic ventilation, see our Vent Calculator.

How it works:

The Air Intake Roof Louver provides fresh air into the attic or plenum. Heat and moisture may cause the structure to decay without proper rooftop ventilation. This roof vent also helps keep insulation dry in the winter to prevent mold growth.

The round design is also aerodynamic, allowing it to withstand wind speeds beyond 200 mph. The Pop Vent can also be painted to match the color of the roof.

For any questions, please see the frequently asked questions page. If you still have questions, email the sales team at sales@roofvents.com or call 845-565-7770

Pop Vents are UL-listed, rated up to 50+ PSF or wind pressure above 200 MPH, and certified by the Texas Department of Insurance, & Florida State Approved.

Colors
CERTIFIED-UL Logo

This product has UL Certification. Check out other details and specifics on UL Product IQ™
(Note: UL now requires you to have a free account to access this page) UL’s Online Certifications Directory.

certificate-of-compliance-universal-vent

Pending

Calculate number of Model  PV-16-C8  Vents Needed for a Given Area

Enter the Width and Length of the attic space you need to ventilate to calculate the area. You may also enter the area directly in the "Area" field. It is not necessary to hit the Return or Enter key (which will refresh this page), just enter numbers in the fields.

Enter width of space to calculate area (or enter Area below)
Enter width of space to calculate area (or enter Area below)

If you know it, you may enter the area directly here

The diameter size of all roof vents determines the Net Free Area, also known as the "NFA". NFA is the measured amount of opening each vent offers at each specific size. to be available for venting air through a specific vent size. The calculator below will find the overall number of vents needed to effectively ventilate the targeted attic space.

Once you have the area, the numbers shown below are the number of vents of that size which would ventilate the specified area with both 1/300 and 1/150 rule.

Results Appear Here





*Please note
The roof vent calculation values shown above are for the exhaust portion of the roof. The same amount of net free air inches is needed for air intake as well. Proper roof ventilation consists of 50% air exhaust and 50% air intake.