Skip to product information
1 of 8

Model PV-16-RF | Pop Vent Roof Louver | 16" Diameter | Retrofit

Model PV-16-RF | Pop Vent Roof Louver | 16" Diameter | Retrofit

SKU:PV-16-RF

843951007410

Price:Regular price $91.00 USD

Regular price Sale price $91.00 USD
Sale Sold out
  • Aluminum Unpainted

    Aluminum Unpainted
  • Plain White STANDARD+$20

  • Plain Black STANDARD+$20

  • Pine Green STANDARD RAL 6028+$20

  • Quartz Grey [Weatherwood] STANDARD RAL 7039+$20

  • Terra Brown STANDARD RAL 8028+$20

Color

View full details
Aluminum Unpainted
Aluminum Unpainted
Aluminum Unpainted
Aluminum Unpainted
Aluminum Unpainted
Aluminum Unpainted
Aluminum Unpainted
Model PV-16-RF | Pop Vent Roof Louver | 16" Diameter | Retrofit
Drawings
Model PV-16-RF | Pop Vent Roof Louver | 16" Diameter | Retrofit
Drawings
Model PV-16-RF | Pop Vent Roof Louver | 16" Diameter | Retrofit
Drawings

16-inch Exhaust Retrofit Roof Louver | Pop Vent Roof Turbine Replacement

The 16-inch Pop Vent Retrofit is for replacing existing attic vents. The PV-16-RF is 16 inches in diameter and has 200 inches of Net Free Area (NFA).

This roof vent will fit over an existing base with a diameter of 16 inches. It's a perfect replacement for turbine vent heads. When roof turbines wear out and stop spinning, they let in rain and snow; let the Pop Vent Roof Louver Retrofits save your roof from the weather.

Benefits:

  • Keeps your home comfortable and energy-efficient
  • Removes heat in the summer and moisture in the winter
  • Prevents rain and snow from entering the attic
  • Inner louvers prevent insects and animals from entering the vent
  • Round aerodynamic design can withstand harsh weather

Installation:

The Pop Vent Retrofits will fit over an existing base, allowing easy installation without damaging the roofing material. Pop Vents install quickly, saving you money. 

How it works:

The 16-inch Pop Vent is a static vent that will continually ventilate the air while preventing rain or snow from entering. The vertical louvers also keep out insects and animals, allowing for proper airflow. In addition, the round design is aerodynamic to withstand wind speeds beyond 200 mph.

For help with installing, please view the Installation Guides. Hardware is included to attach to the base or pipe. For any questions, please see the frequently asked questions page. If you still have questions, email the sales team at sales@roofvents.com or call 845-565-7770

Colors

Pending

Pending

Pending

Pending

Calculate number of Model  PV-16-RF  Vents Needed for a Given Area

Enter the Width and Length of the attic space you need to ventilate to calculate the area. You may also enter the area directly in the "Area" field. It is not necessary to hit the Return or Enter key (which will refresh this page), just enter numbers in the fields.

Enter width of space to calculate area (or enter Area below)
Enter width of space to calculate area (or enter Area below)

If you know it, you may enter the area directly here

The diameter size of all roof vents determines the Net Free Area, also known as the "NFA". NFA is the measured amount of opening each vent offers at each specific size. to be available for venting air through a specific vent size. The calculator below will find the overall number of vents needed to effectively ventilate the targeted attic space.

Once you have the area, the numbers shown below are the number of vents of that size which would ventilate the specified area with both 1/300 and 1/150 rule.

Results Appear Here





*Please note
The roof vent calculation values shown above are for the exhaust portion of the roof. The same amount of net free air inches is needed for air intake as well. Proper roof ventilation consists of 50% air exhaust and 50% air intake.