Air Exhaust Roof Louver | 12″ Diameter 2″ Tall Collar | 113 Sq. In. NFA | Model PV-12-C2

$46.00

Specifications
Image Gallery
Florida Approval
Texas Approval
UL Certification
Description
Colors
Drawings
Installation
Add To Cart
Florida Approval by the Department of Business and Professional Regulation
CERTIFIED-UL Logo

This product has UL Certification. Check out other details and specifics on UL Product IQ™ (Note: UL now requires you to have a free account to access this page) UL’s Online Certifications Directory.

certificate-of-compliance-pop-vent

The Pop Vent “Roof Louver” is used for ventilating steep slope roofs. PV-12-C02 is a 12 inch in diameter roof vent that has a 2 inch tall collar. This means that the vent has a 2 inch clearance between the base and the inner louvers. The PV-12-C02 has 113 inches of net free area (NFA) and comes with an 18 X 18 square base or flange. When used for roof exhaust the PV-12-C02 can be used in climate zones 1 through 8 if the roof pitch is 4/12 or greater and the vent is no more than 18 inches down from the peak of the roof.

Model PV-12-C02 will alleviate moisture in the winter and heat in the summer and extend the life of the roof. The Pop Vent’s top (lid) is manufactured and spun out of one solid piece of aluminum making it corrosion resistant.

The Pop Vents louvers allow hot air to escape freely and efficiently while keeping out birds, insects and animals out of the attic. The round aerodynamic design can with stand harsh weather and wind pressure exceeding 200 mph.

The 12 inch Pop Vent is great for residential roof applications because it is low profile and that it can be painted to match the color of the asphalt shingles.

  • Excellent choice to removing radiant heat from attic spaces in the summer
  • Helps to keep insulation dry in the winter
  • Pitch capacity range: 3/12 to 12/12
  • Inner cylinder louver design does not allow accumulation of particle build up as found in use of insect screen
  • Built-in inner vertical louver cylinder has a 1/8th in. opening between the louver blades meets the requirements of California building code 706A.2 vents to resist the intrusion of burning embers and flame through ventilation openings confirmed by Underwriters Laboratories
  • Helps to reduce energy costs

Pop Vents are UL Listed and rated up to 50+ PSF or wind pressure above 200 MPH.  Certified by Texas Department of Insurance, Florida State Approved & Conforms to the Standards of CALFIRE.

Colors
Color Chart

Pop Vent - Technical Drawing Downloads

Product LinkDrawing- Unmarked Drawing- Measurements Drawing- Cut Away with Measurements
PV-12-C2dwg file icon - click to download CAD (dwg) fileunmarked drawingpdf file icon - click to download pdf file
dwg file icon - click to download CAD (dwg) fileWith Measurements drawingpdf file icon - click to download pdf file
dwg file icon - click to download CAD (dwg) fileCut Away and Measurements drawingpdf file icon - click to download pdf file

Pop Roof Vent - Installation Instructions

Product LinkInstallation Instructions (Shingled Roof) - pdfInstallation Instructions(Flat Roof) - pdf
PV-12-C2Installation Instructionpdf file icon - click to download pdf fileN/A

Select Options and Click "Add To Cart" button below

Base Price (Before options):

$46.00