Skip to product information
1 of 8

Aura Gravity Ventilator 28 NFA | 6" Diameter | 12" Tall Collar | Flat Flange | 28 Sq. In. NFA

Aura Gravity Ventilator 28 NFA | 6" Diameter | 12" Tall Collar | Flat Flange | 28 Sq. In. NFA

SKU:AV-6-C12

843951007854

Price:Regular price $37.00 USD

Regular price Sale price $37.00 USD
Sale Sold out
  • Aluminum Unpainted

    Aluminum Unpainted
  • Plain White STANDARD+$13

  • Plain Black STANDARD+$13

  • Pine Green STANDARD RAL 6028+$13

  • Quartz Grey [Weatherwood] STANDARD RAL 7039+$13

  • Terra Brown STANDARD RAL 8028+$13

Color

View full details
Aluminum Unpainted
Aluminum Unpainted
Aluminum Unpainted
Aluminum Unpainted
Aluminum Unpainted
Aluminum Unpainted
Aluminum Unpainted
Aura Gravity Ventilator 28 NFA | 6" Diameter | 12" Tall Collar | Flat Flange | 28 Sq. In. NFA
Drawings
Aura Gravity Ventilator 28 NFA | 6" Diameter | 12" Tall Collar | Flat Flange | 28 Sq. In. NFA
Drawings
Aura Gravity Ventilator 28 NFA | 6" Diameter | 12" Tall Collar | Flat Flange | 28 Sq. In. NFA
Drawings

6" Roof Vent | Aura Gravity Ventilator | Model AV-6-C12

The 6-inch Aura Gravity Ventilator is 6 inches in diameter and has a 12-inch tall collar. The model AV-6-C12 has 28 inches of Net Free Area (NFA). All 6-inch gravity ventilators have a standard 11" x 11" square flange flashing.

Benefits:

  • Keeps your home comfortable and energy-efficient
  • Removes hot, moist air from the attic
  • Prevents rain & snow, insects & animals from entering the vent
  • Aerodynamic design withstands harsh weather and wind forces beyond 200 mph
  • The vent head is removable for easy installation
  • Noiseless – does not require electricity to exhaust air

Where to Install:

Exhaust vents with a collar height of 12 inches are for low-slope or flat-roof ventilation. However, if installed on the upper portion of the roof with a roof pitch of 0/12 to 5/12, this vent is rated for all climate zones. See the installation guides for help installing.

The 6-inch roof vent is ideal for ventilating attics, bathroom fans, or range hoods. It removes heat during the summer and moisture during the winter to provide ventilation for low-slope or flat roofs.

How it Operates:

The Aura Gravity Ventilator works like a roof turbine but with no moving parts.

Aura Gravity Ventilators rely on the Venturi Effect, which occurs when the wind blows against the outer louvers. This creates a spinning upward draft through the vent, allowing air to flow dynamically out of the vent. Even the smallest breeze can create exhaust ventilation to draw out air from the attic.

The Aura Gravity Roof Vents are made of durable, rust-free aluminum. The vent head has a flat, one-piece spun lid that prevents rain and snow from entering. The round aerodynamic design can withstand harsh weather and wind forces beyond 200 mph. For example, wind speeds of 11 mph for a 6-inch Gravity Ventilator produce 126 CFM of air exhaust for attic ventilation.

The inner louvers of the roof vent prevent insects and animals from entering the attic. The louvers also allow the air to flow freely to the outside.

AVP’s Aura Gravity Vents are UL-listed and rated up to 50+ PSF or wind pressure above 200 MPH. They are certified by the Texas Department of InsuranceFlorida State Approved.

If you have any questions, please see the frequently asked questions page. If you still have questions, email the sales team at sales@roofvents.com or call 845-565-7770.

Colors
CERTIFIED-UL Logo

This product has UL Certification. Check out other details and specifics on UL Product IQ™
(Note: UL now requires you to have a free account to access this page) UL’s Online Certifications Directory.

certificate-of-compliance-aura-vent

Pending

Calculate number of Model  AV-6-C12  Vents Needed for a Given Area

Enter the Width and Length of the attic space you need to ventilate to calculate the area. You may also enter the area directly in the "Area" field. It is not necessary to hit the Return or Enter key (which will refresh this page), just enter numbers in the fields.

Enter width of space to calculate area (or enter Area below)
Enter width of space to calculate area (or enter Area below)

If you know it, you may enter the area directly here

The diameter size of all roof vents determines the Net Free Area, also known as the "NFA". NFA is the measured amount of opening each vent offers at each specific size. to be available for venting air through a specific vent size. The calculator below will find the overall number of vents needed to effectively ventilate the targeted attic space.

Once you have the area, the numbers shown below are the number of vents of that size which would ventilate the specified area with both 1/300 and 1/150 rule.

Results Appear Here





*Please note
The roof vent calculation values shown above are for the exhaust portion of the roof. The same amount of net free air inches is needed for air intake as well. Proper roof ventilation consists of 50% air exhaust and 50% air intake.