$61.00
This product has UL Certification. Check out other details and specifics on UL Product IQ™ (Note: UL now requires you to have a free account to access this page) UL’s Online Certifications Directory.
The 12 inch Pop Vent Air Intake Vent is ideal for maintaining proper attic ventilation. The PV-12-C12 is 12 inches in diameter with a 12 inch tall collar. In other words, this vent has 12 inches of clearance between the base and the inner louvers. In addition, the 12 inch Pop Vent has 113 inches of Net Free Area (NFA) and a standard 18” x 18” square flange.
Air intake vents allow outside air to enter into attics and ventilation spaces.
This 12 inch attic vent is suitable for installation in climate zones 1-8. This intake roof vent is for installation on flat roofs.
To determine the number of vents you may need for proper attic ventilation, see our Vent Calculator.
The Air Intake Roof Louver provides fresh air into the attic or plenum. Without proper rooftop ventilation, heat and moisture may cause decay of the structure. This roof vent also helps to keep insulation dry in the winter to prevent the growth of mold.
Additionally, the round design is aerodynamic to withstand wind speeds up to 200 mph. The 12 inch Pop Vent is great for residential roof applications because of its low profile. It can also be painted to match the color of the asphalt shingles.
For any questions please see the frequently asked questions page. If you still have questions, email the sales team at [email protected] or call 845-565-7770
Pop Vents are UL Listed and rated up to 50+ PSF or wind pressure above 200 MPH. Certified by Texas Department of Insurance, Florida State Approved & Conforms to the Standards of CALFIRE.
Product Link | Drawing- Unmarked | Drawing- Annotated | Drawing- Cut Away | Revit |
---|---|---|---|---|
PV-12-C12 |
The diameter size of all roof vents determines the Net Free Area, also known as the "NFA". NFA is the measured amount of opening each vent offers at each specific size. to be available for venting air through a specific vent size. The calculator below will find the overall number of vents needed to effectively ventilate the targeted attic space.
Once you have the area, the numbers shown below are the number of vents of that size which would ventilate the specified area with both 1/300 and 1/150 rule.
*Please note
The roof vent calculation values shown above are for the exhaust portion of the roof. The same amount of net free air inches is needed for air intake as well. Proper roof ventilation consists of 50% air exhaust and 50% air intake.
$61.00